Zero Purge Compressed Heat Regeneration Adsorption Dryer

Heat-of-compression regeneration: Uses available compressor discharge heat to regenerate the desiccant, reducing the need for external regeneration energy.

Zero-purge design: The SMRZ system is designed to avoid dried compressed-air purge during normal regeneration when the specified inlet temperature, pressure and flow conditions are met.

Twin-tower adsorption: One tower dries compressed air while the other regenerates, supporting continuous dry-air supply.

Thermal and valve control: High-temperature valves, cooling/separation components and PLC sequencing coordinate heating, cooling, switching and drainage.

Application engineering: Final performance depends on compressor type, available heat, inlet conditions, flow profile and required pressure dew point; confirm these conditions during model selection.

WhatsApp

+86 180 5167 0936

Product Specifications

Model Specifications

The SMRZ catalog lists 12 heat-of-compression regeneration dryer models from 37 to 300 Nm³/min. Compressor discharge heat supplies the regeneration heat; compressor compatibility and available inlet temperature must be checked.

Scroll horizontally on smaller screens.

SMRZ series catalog specifications
ModelCapacity (Nm³/min)Listed Power (kW)Cooler ConnectionWeight (kg)Air ConnectionL × W × H (mm)
SMRZ370370.25DN653500DN1002650 × 1700 × 3000
SMRZ450450.25DN654200DN1002850 × 2000 × 3000
SMRZ600600.25DN654800DN1252900 × 2100 × 3200
SMRZ750750.25DN805600DN1253150 × 2200 × 3200
SMRZ10001000.25DN1006900DN1503500 × 2400 × 3400
SMRZ12001200.25DN1008500DN1503800 × 2800 × 3400
SMRZ15001500.25DN10010500DN2004000 × 2900 × 3700
SMRZ18001800.25DN12512500DN2004100 × 3000 × 3700
SMRZ20002000.25DN12513600DN2004400 × 3000 × 3700
SMRZ22002200.25DN12515800DN2004800 × 3200 × 3900
SMRZ25002500.25DN12518300DN2504900 × 3400 × 4100
SMRZ30003000.25DN15019600DN2505200 × 4200 × 4350

The listed 0.25 kW electrical power does not represent total system energy use. Include compressor energy and cooling-water utilities when comparing operating costs.

Catalog Operating Conditions

  • Working pressure: 0.6–1.0 MPa.
  • Inlet temperature: 110–180°C.
  • Inlet oil content: ≤0.1 mg/m³.
  • Cooling-water temperature: ≤32°C.
  • Cooling-water pressure: 0.3–0.5 MPa.
  • Pressure dew point: −20°C / −40°C, subject to the selected option.
  • Regeneration-air consumption: catalog lists 0%; confirm the guarantee for the complete operating cycle.

Check Compressor Compatibility

Send compressor type and model, discharge flow, pressure and temperature, and the load/unload pattern. Confirm whether adequate regeneration heat remains available at the lowest expected load.

Provide cooling-water temperature, pressure and available flow, required pressure dew point, pipe connections and installation space. The cooler connection size is not a cooling-water flow specification.

Original Catalog

Check Heat-of-Compression Drying

Send the compressor model, discharge conditions, usable air demand, cooling-water conditions and target dew point.