Model Specifications
The following 14 models are listed in the SMC heatless adsorption dryer catalog. Capacity is stated in Nm³/min; confirm the reference conditions and capacity at your actual inlet pressure and temperature.
Scroll horizontally on smaller screens to see all columns.
| Model | Capacity (Nm³/min) | Power Supply | Listed Power (kW) | Weight (kg) | Connection | L × W × H (mm) |
|---|---|---|---|---|---|---|
| SMC038 | 3.8 | 220V / 50Hz / 1PH | 0.15 | 335 | DN25 | 868 × 740 × 1492 |
| SMC065 | 6.5 | 220V / 50Hz / 1PH | 0.15 | 425 | DN40 | 868 × 740 × 1842 |
| SMC085 | 8.5 | 220V / 50Hz / 1PH | 0.15 | 475 | DN40 | 1018 × 678 × 1892 |
| SMC115 | 11.5 | 220V / 50Hz / 1PH | 0.15 | 600 | DN50 | 1351 × 697 × 2050 |
| SMC135 | 13.5 | 220V / 50Hz / 1PH | 0.15 | 624 | DN50 | 1351 × 697 × 2050 |
| SMC180 | 18.0 | 220V / 50Hz / 1PH | 0.15 | 645 | DN65 | 1351 × 697 × 2265 |
| SMC220 | 22.0 | 220V / 50Hz / 1PH | 0.15 | 685 | DN65 | 1351 × 697 × 2273 |
| SMC250 | 25.0 | 220V / 50Hz / 1PH | 0.15 | 860 | DN80 | 1402 × 833 × 2372 |
| SMC320 | 32.0 | 220V / 50Hz / 1PH | 0.15 | 1075 | DN80 | 1520 × 838 × 2500 |
| SMC450 | 45.0 | 220V / 50Hz / 1PH | 0.15 | 1285 | DN100 | 1885 × 866 × 2580 |
| SMC550 | 55.0 | 220V / 50Hz / 1PH | 0.15 | 1825 | DN100 | 2000 × 1105 × 2620 |
| SMC650 | 65.0 | 220V / 50Hz / 1PH | 0.15 | 2055 | DN100 | 2000 × 1105 × 2620 |
| SMC850 | 85.0 | 220V / 50Hz / 1PH | 0.15 | 3350 | DN125 | 2540 × 1533 × 2945 |
| SMC1000 | 100.0 | 220V / 50Hz / 1PH | 0.15 | 3650 | DN150 | 2540 × 1533 × 2985 |
Energy-use note: the listed 0.15 kW electrical power does not include the compressor energy used to produce regeneration air. Heatless regeneration still consumes compressed air.
Catalog Operating Conditions
- Working pressure: 0.6–1.0 MPa.
- Inlet temperature: 0–45°C.
- Outlet pressure dew point: −20°C to −40°C under the specified configuration and operating conditions.
- Regeneration air: catalog range approximately 14%–20%; confirm the actual purge requirement for the selected model.
- Inlet oil content: less than 0.1 mg/m³.
- Desiccant: activated alumina.
- Operating cycle: 10–20 minutes.
How Heatless Regeneration Works
One tower adsorbs moisture while a portion of dried compressed air regenerates the other tower at reduced pressure. The towers alternate to maintain the air supply. No external regeneration heater is required.
Allow for Regeneration Air
Size the compressed-air supply for both the downstream requirement and the dryer’s regeneration demand. Tell us whether your stated flow is compressor delivery or the usable flow needed after the dryer.
Provide inlet pressure, highest inlet temperature, required pressure dew point and the upstream filter arrangement. Separation and filtration help protect the desiccant from liquid water and oil.
Original Catalog Documents
Request a Capacity and Dew-Point Check
Send the usable air flow you need, working pressure, inlet temperature and target dew point. Include a model if you have one in mind.
Send Your Requirements