Heatless Adsorption Dryer

Twin-tower heatless adsorption drying: One tower dries compressed air while the other regenerates with a portion of dried product air, allowing continuous operation.

Current catalog range: SMC models are listed from 3.8 to 100 Nm³/min, with 0.6–1.0 MPa working pressure, inlet oil content ≤0.1 mg/m³ and a standard listed pressure-dew-point range of -20°C to -40°C.

Regeneration-air demand: The current catalog lists approximately 14%–20% regeneration gas under its stated conditions. Actual operating cost depends on flow, pressure, duty cycle and compressed-air value.

Desiccant protection: Correct upstream separation and filtration are important because liquid water and oil contamination can reduce adsorption performance and desiccant life.

Final sizing should use actual flow, inlet pressure, inlet temperature, operating schedule and the required pressure dew point. Requirements below the standard catalog range should be confirmed with engineering rather than assumed.

WhatsApp

+86 180 5167 0936

Product Specifications

Model Specifications

The following 14 models are listed in the SMC heatless adsorption dryer catalog. Capacity is stated in Nm³/min; confirm the reference conditions and capacity at your actual inlet pressure and temperature.

Scroll horizontally on smaller screens to see all columns.

SMC series catalog model specifications
ModelCapacity (Nm³/min)Power SupplyListed Power (kW)Weight (kg)ConnectionL × W × H (mm)
SMC0383.8220V / 50Hz / 1PH0.15335DN25868 × 740 × 1492
SMC0656.5220V / 50Hz / 1PH0.15425DN40868 × 740 × 1842
SMC0858.5220V / 50Hz / 1PH0.15475DN401018 × 678 × 1892
SMC11511.5220V / 50Hz / 1PH0.15600DN501351 × 697 × 2050
SMC13513.5220V / 50Hz / 1PH0.15624DN501351 × 697 × 2050
SMC18018.0220V / 50Hz / 1PH0.15645DN651351 × 697 × 2265
SMC22022.0220V / 50Hz / 1PH0.15685DN651351 × 697 × 2273
SMC25025.0220V / 50Hz / 1PH0.15860DN801402 × 833 × 2372
SMC32032.0220V / 50Hz / 1PH0.151075DN801520 × 838 × 2500
SMC45045.0220V / 50Hz / 1PH0.151285DN1001885 × 866 × 2580
SMC55055.0220V / 50Hz / 1PH0.151825DN1002000 × 1105 × 2620
SMC65065.0220V / 50Hz / 1PH0.152055DN1002000 × 1105 × 2620
SMC85085.0220V / 50Hz / 1PH0.153350DN1252540 × 1533 × 2945
SMC1000100.0220V / 50Hz / 1PH0.153650DN1502540 × 1533 × 2985

Energy-use note: the listed 0.15 kW electrical power does not include the compressor energy used to produce regeneration air. Heatless regeneration still consumes compressed air.

Catalog Operating Conditions

  • Working pressure: 0.6–1.0 MPa.
  • Inlet temperature: 0–45°C.
  • Outlet pressure dew point: −20°C to −40°C under the specified configuration and operating conditions.
  • Regeneration air: catalog range approximately 14%–20%; confirm the actual purge requirement for the selected model.
  • Inlet oil content: less than 0.1 mg/m³.
  • Desiccant: activated alumina.
  • Operating cycle: 10–20 minutes.

How Heatless Regeneration Works

One tower adsorbs moisture while a portion of dried compressed air regenerates the other tower at reduced pressure. The towers alternate to maintain the air supply. No external regeneration heater is required.

Allow for Regeneration Air

Size the compressed-air supply for both the downstream requirement and the dryer’s regeneration demand. Tell us whether your stated flow is compressor delivery or the usable flow needed after the dryer.

Provide inlet pressure, highest inlet temperature, required pressure dew point and the upstream filter arrangement. Separation and filtration help protect the desiccant from liquid water and oil.

Original Catalog Documents

Request a Capacity and Dew-Point Check

Send the usable air flow you need, working pressure, inlet temperature and target dew point. Include a model if you have one in mind.

Send Your Requirements

Related Products

滚动至顶部

Request a Product Recommendation

Tell us the product or application you need and the operating details you know. We can help define missing selection inputs.

GET A QUOTE

Fill out the form below, and we will be in touch shortly.