Micro-heat Regeneration Adsorption Dryer

Micro-heat regeneration: The SMA series combines electric heating with a reduced flow of dry purge air to regenerate the off-line desiccant tower.

Current catalog range: Listed SMA models cover 3.8–100 Nm³/min with rated power from 2 to 30 kW across the series.

Twin-tower continuous drying: One adsorption tower dries compressed air while the other regenerates, then the towers switch automatically.

Lower purge demand than heatless drying: Heating improves regeneration effectiveness, reducing the amount of dried compressed air required compared with a conventional heatless cycle under comparable conditions.

Final selection should confirm actual flow, working pressure, inlet temperature, inlet contamination, duty cycle and required pressure dew point. Upstream liquid-water and oil control are important for desiccant life and stable performance.

WhatsApp

+86 180 5167 0936

Product Specifications

Model Specifications

The SMA catalog lists 14 micro-heat regeneration dryer models, covering 3.8–100 Nm³/min. Confirm capacity at your actual pressure, inlet temperature and required pressure dew point.

Scroll horizontally on smaller screens to see all columns.

SMA series catalog specifications · 380V / 50Hz / 3PH
ModelCapacity (Nm³/min)Listed Power (kW)Weight (kg)ConnectionL × W × H (mm)
SMA0383.82350G1.5960 × 600 × 1520
SMA0656.53420G1.51010 × 600 × 1930
SMA0858.53485G1.51120 × 600 × 1970
SMA11511.53540G21120 × 700 × 1990
SMA13513.54580G21230 × 700 × 1990
SMA18018.06905DN651430 × 900 × 2450
SMA22022.061025DN651485 × 900 × 2480
SMA25025.081120DN801530 × 900 × 2495
SMA32032.0101205DN801580 × 1000 × 2550
SMA45045.0121525DN1001835 × 1000 × 2655
SMA55055.0202350DN1002350 × 1105 × 2780
SMA65065.0202950DN1002460 × 1196 × 2800
SMA85085.0244170DN1252644 × 1366 × 3090
SMA1000100.0304250DN1502644 × 1366 × 3090

Catalog Operating Conditions

  • Working pressure: 0.6–1.0 MPa.
  • Inlet temperature: 0–45°C.
  • Pressure dew point: −20°C to −40°C, depending on the selected configuration and operating conditions.
  • Regeneration air: catalog range approximately 7%–11%; confirm the actual requirement.
  • Inlet oil content: less than 0.1 mg/m³.
  • Desiccant: alumina.
  • Operating cycle: 2–8 hours.

Electric Heating and Purge Air

One tower dries compressed air while the off-line tower regenerates with electrically heated dry purge air. The towers switch automatically to maintain the air supply.

Heating reduces the purge-air requirement compared with the heatless catalog range of 14%–20%, but adds electrical consumption. Compare heater electricity and the compressor energy used for purge air together; lower purge demand alone is not proof of lower total energy use.

Filtration and Selection

The dryer removes moisture. Oil control depends on upstream separation and filtration; it does not by itself guarantee oil-free air.

  • State the usable air flow required after the dryer and the compressor delivery.
  • Provide working pressure, highest inlet temperature and target pressure dew point.
  • Confirm available 380V / 50Hz / 3PH supply, duty cycle and installation space.
  • Describe upstream water separation and oil filtration.

Original Catalog Documents

Compare Heatless and Micro-Heat Drying

Send your flow, pressure, inlet temperature, target dew point and operating hours. We can check the model and regeneration requirements for your application.