Variable Speed Refrigerated Air Dryer

Variable-speed refrigeration: DC inverter control adjusts refrigeration output as the compressed-air load changes, reducing unnecessary full-load operation during periods of lower demand.

Controlled cooling: The refrigeration system regulates evaporation temperature to maintain stable moisture separation within the dryer’s rated operating conditions. Pressure dew point depends on actual flow, pressure, inlet temperature and ambient temperature.

Soft-start operation: Variable-frequency starting reduces inrush current and mechanical shock compared with repeated direct starts.

Operating monitoring: The controller displays key operating information such as power, current and system status for easier routine supervision.

Aluminum plate-fin heat exchange: Designed for efficient heat transfer and compact compressed-air treatment.

WhatsApp

+86 180 5167 0936

Product Specifications

SUPERMAN · SMDV SERIES

Variable-Speed Drying for Changing Air Demand

The SMDV refrigerated air dryer adjusts refrigeration compressor output to match compressed-air demand. An aluminum plate heat exchanger, automatic temperature control and compressor soft start support operation under changing loads.

Catalog capacity: 13.5–100 Nm³/min. Frequency range: 30–90 Hz or 30–120 Hz, depending on the model.

Request a Model Recommendation   View Model Specifications

When to Consider a Variable-Speed Dryer

  • Compressed-air demand changes between shifts or production cycles.
  • You want refrigeration output to follow the drying load.
  • You can provide operating hours and load information to assess energy use.

Controls and Operating Data

  • Automatic evaporation-temperature adjustment within the catalog range of 2–10°C.
  • Real-time power and current display.
  • Compressor soft start and protection against liquid compression.

Evaporation temperature and pressure dew point are different measurements. Confirm the required pressure dew point and rated capacity for your actual operating conditions.

Technical Specifications

Values are transcribed from the original SMDV data sheet. The power column is labeled at 60Hz in the catalog, while the electrical supply is listed as 50Hz. Confirm the rating basis and the supplied electrical configuration with SUPERMAN before ordering.

Scroll the table horizontally on smaller screens.

SMDV catalog model specifications · R410A refrigerant
ModelCapacity (Nm³/min)Power SupplyRated Power at 60Hz (kW)Weight (kg)Frequency (Hz)ConnectionL × W × H (mm)
SMD135LV13.5220V / 1PH / 50Hz2.3912030–90G21150 × 900 × 1280
SMD170LV17.0220V / 1PH / 50Hz2.4915030–90G2.51150 × 900 × 1280
SMD200LV20.0220V / 1PH / 50Hz3.4117030–90G2.51150 × 900 × 1280
SMD250LV25.0380V / 3PH / 50Hz3.4120030–90G31350 × 900 × 1280
SMD340LV34.0380V / 3PH / 50Hz4.7335030–90DN1001315 × 1200 × 1800
SMD400LV40.0380V / 3PH / 50Hz5.935030–90DN1001315 × 1200 × 1800
SMD500LV50.0380V / 3PH / 50Hz7.1535030–90DN1001315 × 1200 × 1800
SMD600LV60.0380V / 3PH / 50Hz9.6860030–90DN1502075 × 1250 × 1845
SMD750LV75.0380V / 3PH / 50Hz9.860030–90DN1502075 × 1250 × 1845
SMD800LV80.0380V / 3PH / 50Hz9.4860030–120DN1502075 × 1250 × 1845
SMD1000LV100.0380V / 3PH / 50Hz1260030–120DN1502075 × 1250 × 1845

How to Assess Energy Savings

Savings depend on the load profile, operating hours, inlet and ambient temperatures, dew-point requirement and the dryer used for comparison. The catalog comparison assumes 8,000 annual operating hours at an average load and is for reference only; it does not establish a guaranteed saving or payback period for your site.

Information for Selection

  • Air flow and its reference conditions; minimum and maximum demand.
  • Working pressure, highest inlet temperature and ambient temperature.
  • Required pressure dew point, operating hours and available power supply.

The catalog uses correction factors for pressure, inlet temperature, ambient temperature and dew point. Send these conditions so the capacity can be checked.

Original Product Documents

Check Your Dryer Selection

Tell us your flow, pressure, temperature, operating hours and target dew point. Include the model you are considering; unknown details can stay blank.

Send Your Requirements

Related Products

滚动至顶部

Request a Product Recommendation

Tell us the product or application you need and the operating details you know. We can help define missing selection inputs.

GET A QUOTE

Fill out the form below, and we will be in touch shortly.